Contact price: 0983.912.259

Compact, stable and robust UV sensor with sealed optical system that is highly solar resistant

The sensor is used in a 1:1 ratio with EIT 2.0 LLC DIN Rail

Compact sensor options   include:

  • Case shape: CS-1 (Pleached) or CS-2 (Unbleached)
  • Available UV ranges: Mercury ( UVA, UVB, UVC or UVV ) / LED (L-365, L-385, L-395 or L-405)
  • Internal aperture size is based on power source and installation location

Refer to the temperature limit documentation. 

The EIT 2.0 LLC UV sensor  can be used in applications with high temperatures or confined spaces

SPECIFICATIONS

 

Feature

CS-1With purge CS-2Without Purge BTR (Behind the Reflector) DIN Rail standard DRM-007 EMI DIN Rail DRM-006
Size 0.57 x 1.10 x 0.75”(1.45 x 2.78 x 1.91 cm) 0.57 x 0.60 x 0.75”(1.45 x 1.52 x 1.91 cm) 0.55 x 0.55 x 1.55”(1.40 x 1.40 x 3.90 cm) 3.56 x 3.11 x 0.98”(9.04 x 7.90 x 2.29 cm) 3.56 x 3.11 x 0.98”(9.04 x 7.90 x 2.29 cm)
Weight 0.8 oz (22.68 g) 0.7 oz (19.86 g) 1.0 oz (28.35 g) 3.6 oz (101 g) 3.6 oz (101 g)
Material Aluminum case Aluminum case Aluminum case DIN Rail Housing DIN Rail Housing
Available Sensor Standard, LED or EMI Standard, LED or EMI  Only with Emi sensor Used with standard or LED sensors Readw for use only with Emi sensors
UV Range/Power Source UVA/UVB/UVC or UVV 

L365/L385/ L395 or L405

UVA/UVB/UVC or UVV 

L365/L385/ L395 or L405

 UVA/UVB/UVC or UVV 20-28 Volts AC or DC 70 mA maximum 20-28 Volts AC or DC 70 mA maximum
Operating range (Temp °C) UVA, UVB, UVV:0-100°C

UVC & L-Bands: 0-70°C

UVA, UVB, UVV:0-100°C

UVC & L-Bands: 0-70°C

UVA, UVB, UVV:0-100°C UVC: 0-70°C  0-50°C  0-50°C
Sensor aperture/ Output  The sensor is available in a variety of aperture sizes, specified at the time of order. The aperture size used depends on the lamp power and installation location 0-10 VDC or 4-20 milli- Amp is proportional to UV intensity 0-10 VDC or 4-20 milli- Amp is proportional to UV intensity
 Cap type Standard or LED sensor: 2 wire, Teflon shielded, 10′ (3 m) standard EMI sensor: 3 twisted wire, Teflon shielded, 10′ (3 m) standard  At DIN: Two Wire At DIN: Two wires+ Grounded EMI sensor
Acceptance Angle / Accuracy The approximate acceptance angle is 5° degrees Approximate acceptance angle of13° degrees Approximate acceptance angle of4° degrees +/- 3% full scale (10 Volts), Alarm setScore +/- 5% from threshold setting +/- 3% of full scale (10 Volts), Alarm setpoint+/- 5% from threshold setting

Reviews

There are no reviews yet.

Be the first to review “UV compact sensor”